Maintenance-Object Repair Procedures
555-233-143
8-294
Issue 1 May 2002
show a diagrams of this
2-part test, substituting “CES mode” for “PNC mode.”
Table 8-129.
ATM Board Framer Loop-Around Test (#1260)
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
Time slots could not be allocated. Traffic could be heavy or time slots could be
out-of-service.
1. Run display errors, and perform repairs associated with TDM-BUS errors.
2. Retry the command up to 3 times at 1-minute intervals.
1003
ABORT
Tone receiver could not be allocated.
1. Run display errors, and perform the repairs associated with TTR-LEV and
TONE-PT errors.
The test cannot run unless there is at least one Tone Detector available in
the EPN that holds the ATM-TRK circuit pack.
2. Retry the command up to 3 times at 1-minute intervals.
1015
ABORT
ATM-TRK circuit pack not busied out
1. Busyout the ATM circuit pack.
2. Rerun the command.
1033
ABORT
ATM-TRK circuit pack not found
1. See if the switch can see the circuit pack. Run status trunk group.
2. Retry the command.
1139
ABORT
Major alarm on the EPN’s packet bus
1. Run display alarms, and perform the repairs associated with PKT-BUS
errors.
2. Run display errors, and perform the repairs associated with PKT-BUS
errors.
3. Retry the command.
1141
ABORT
Packet-interface circuit pack out of service
1. See
‘‘PKT-INT (Packet Interface)’’
1394
ABORT
ATM-TRK circuit pack out of service
1. Run the ATM Board Reset test (#1256).
2000
ABORT
Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060
ABORT
Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the repairs
associated with PKT-INT errors.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...