Alarms, Errors, and Troubleshooting
555-233-143
4-30
Issue 1 May 2002
Switch Fabric
Board
PWR
Green
Steady on
Normal state. The switch fabric board is
powered up.
FAULT
Amber
Off
Normal state
Port Board
PWR
Green
Steady on
Normal state. The port board is powered up.
FAULT
Amber
Off
Normal state
Port Board
Per Port
RX
Green
Off
No ATM cells are being received. This is not
a normal state if the terminating port network
is supposed to be up and running.
RX
Green
Intermittent
blink
ATM cells are being received intermittently.
This is a typical pattern for
S8700
Multi-Connect
if only VBR (variable bit rate)
signaling connections are present, but no talk
paths are up (perhaps because no calls are in
progress).
RX
Green
Steady on
ATM cells are being received frequently
enough that the LED is lit constantly. This is a
typical pattern for
S8700 Multi-Connect
if
CBR (constant bit rate) talk paths are present.
CD
Green
Off
Loss of carrier on the fiber. The A500 detects
only if the A500-receive (right-hand) fiber is
not working. The state of the A500-transmit
(left hand) fiber is not detected.
CD
Green
Steady on
Normal state. There is a optical carrier
detected on the fiber from the TN230X.
RPRD
Amber
Off
Normal state
Power Supply
AC OK
Green
Steady on
Normal state. AC power is okay.
DC OK
Green
Steady on
Normal state. DC power is okay.
Table 4-5.
A500 LED Quick Reference —
Continued
Component
Label
Color
State
Meaning
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...