BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 1 May 2002
8-343
555-233-143
Table 8-145.
Test #619 BRI Port Local TDM Loop Around
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
The system resources required to run this test are not available. The port may
be busy with a valid call.
1. Use the display port PCSSpp command to determine the station
extension or trunk group/member number of the port. Use the status
bri-port PCSSpp command to determine the service state of the port. If
the service state indicates that the port is active, then the port is
unavailable for certain tests. (Refer to the “Status Commands” section in
Chapter 7, ‘‘Maintenance Commands’’
, for a full description of every
possible state.) Wait until the port is idle before retesting.
2. If the port is idle, then retry the command at 1-minute intervals up to 5
times.
3. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004
ABORT
The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine when the port
is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the problem.
1005
ABORT
This test is not valid for this type of translation. Ports administered as “ASAI” or
“ADJK” cannot run this test, because the B channels associated with the port
are not used by ASAI or Avaya Adjunct Links. This is a normal condition.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...