Maintenance-Object Repair Procedures
555-233-143
8-346
Issue 1 May 2002
Level 1 Status Inquiry Test (#621)
This test determines the state of the transmission facility of a BRI port at the
physical layer (that is, Level 1). Level 1 can be in one of three possible states:
Activated, Pending Activation, or Deactivated.
The Activated state is the correct state for an ISDN-BRI port. In this state the
Level 1 interface can communicate with the BRI endpoint or ASAI or Avaya
adjunct administered on this port. This test passes if the state of Level 1 (L1) is
Activated. This test also passes if software has taken this port out of service. See
the description of the Level 1 “Deactivated State” below for more details.
The Pending Activation state indicates a problem with the endpoints or adjunct,
the wiring to the sets or adjunct, or the BRI-LINE circuit pack. When in this state,
the Level 1 interface is either not receiving any L1 framing from the endpoint or
adjunct (Endpoint Idle), or it is communicating with the endpoint or adjunct but
cannot transition to the Activated state (Endpoint Active).
The Deactivated state indicates a problem with the BRI-LINE circuit pack. When
in this state, the Level 1 interface is idle and is not trying to communicate with the
BRI endpoints or adjunct. When an ISDN-BRI port is placed in the out-of-service
state, Level 1 is also put into the Deactivated state. This could be due either to
the system detecting a fault with the port or to a busyout port PCSSpp request.
Table 8-147.
Test #621 Level 1 Status Inquiry
Error
Code
Test
Result
Description / Recommendation
1187
ABORT
The board, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port and
BRI-BD (board busied out). If this error type is present for BRI-PORT only,
then release the port via the release port pp command and run the test
again. If the error is present for both BRI-BD and BRI-PORT, then release
the board via the release port PCSS command and run the test again.
NOTE:
When you release a port, you release every port associated with it. If
certain ports still need to be busied out, use the busyout port PCSSpp
command to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...