Maintenance-Object Repair Procedures
555-233-143
8-358
Issue 1 May 2002
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data field
indicates what timer has just expired. (For more information, refer to the
Avaya ISDN-BRI Specification.
3329
(k)
Any
Signaling Link
Status
(626)
WARNING
MAJOR/
WARNING
OFF
3584
0,1
None
3585-
3839(i)
0
None
3840-
4095
(m) (n)
0
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
Aux Data
Timer Type
2
First T303 (SETUP timer)
3
Second T303 (SETUP timer)
4
T305 (DISConnect timer)
5
First T308 (RELease timer)
6
Second T308 (RELease timer)
10
T316 (RESTart timer)
12
T309 (Layer-2 Failure timer)
16
TM100 (Management Information
message Timer 1)
17
TM200 (Management Information
message Timer 2)
102
TASAI (ASAI Routing timer)
Table 8-152.
BRI-SET/ASAI-ADJ Error Log Entries —
Continued
Error
Type
Aux
Data
Associated
Test
Alarm
Level
BBRI-SET
ASAI-ADJ
ASAI-ADJ
ATT-ADJ
LGATE-|AJ
ATTE-AJ
On/
Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...