Maintenance-Object Repair Procedures
555-233-143
8-364
Issue 1 May 2002
Table 8-154.
ISDN-BRI CAUSE VALUES
Error
Code
Test Result
Description / Recommendation
1
Another station is using requested channel on the
BRI-PORT. (Not applicable for ASAI or Avaya adjuncts.)
For BRI endpoints:
1. Try to originate a call to or from this port.
2. If the error persists, busyout and release the port.
3. If the problem still persists, replace stations on the port.
4. If the problem still persists, escalate to the next tier.
34
No circuit or
channel
available
A resource on the switch is unavailable for a call. For BRI
endpoints: This cause value is not logged. For ASAI or
Avaya Adjuncts: This condition means that there are no
available trunks for an outgoing call request.
1. Verify that the adjunct is administered to support the
trunk capabilities of the switch.
2. Investigate trunk group status by issuing status trunk
commands from the SAT or by requesting a trunk group
query or queries from the adjunct.
3. Perform trunk diagnostic procedures outlined in this
manual.
4. If step 3 does not resolve the problem, escalate to the
next tier.
42
Switch
Equipment
Congestion
Switch takes control to limit received traffic. For BRI
endpoints: This cause value is not logged. For ASAI or
Avaya Adjuncts:
1. Refer to the CallVisor protocol reference manual.
2. If step 1 does not resolve the problem, escalate to the
next tier.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...