ATM Tips
Issue 1 May 2002
4-39
555-233-143
A500 Administration
Is the A500 administered correctly?
1. Enter show signaling summary on the A500 console.
shows
the screen output.
Figure 4-17.
Screen output for the show signaling summary command
a. If an A500 port to which a S8700 Multi-Connect port network is
attached is not listed in this display, it is likely that the port was
administered incorrectly as having no UNI signaling (admin link
command).
Ensure that fields listed have the following values.
2. If the A500 was administered using hard-coded PNNI routes to identify
each endpoint, enter show signaling routes on the A500 console.
shows the screen output from the command.
Field
Value
IntType
Network
If it is
User
, links will not come up between the EPNs.
Signaling
UNI3.1
If it is
UNI3.0
, links will not come up between the EPNs.
ILMI
Preferred value of is
No
, however this alone does not
prevent links from coming up between the EPNs.
SAP State
May or may not be
UP
. Their values depend on more
than just whether the port was marked as UP. (See
highlighted data for SAP State in
A500:show signaling summary
Port loc VCI SAP IntType Signaling ILMI SAP State State
------ ------- --- ------- ----------- ---- ------------ -----
A1.1 1 1 Network UNI3.1 No UP UP
A1.2 2 2 Network UNI3.1 No UP UP
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...