e. Error Type 513: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
Aux Data:
f. Error Type 769: Logic error. By itself this error may be ignored, but it may
result in other error types being reported.
g. Error Type 1293-1295: Critical hardware or firmware error.
Error Type descriptions are as follows:
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
h. Error Type 1537: Switch removed hyperactive circuit pack that reported
threshold number of errors.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
i. Error Type 1794: Packet-bus transmit buffers have overflowed.
1. Attempt to clear the alarm (reset board UUCSS).
2. If the error recurs within 15 minutes, replace the circuit pack.
j. Error Type 1798: Unable to write translation RAM.
1. Attempt to clear alarm (reset board UUCSS).
2. If alarm recurs within 15 minutes, replace the circuit pack.
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4356
Angel Message Corruption error
4357
Instruction set error
If the switch detects:
Then the switch:
1 error,
Resets circuit pack.
3 errors in 15 minutes,
Raises MINOR alarm.
1293
Insane onboard processor
1294
Onboard translation RAM error
1295
(Aux 3) RSCL link down
(Aux 0) RSCL keep alive failure
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...