Maintenance-Object Repair Procedures
555-233-143
8-416
Issue 1 May 2002
n. Error Type 2817-2819: Congestion Query test (#600) failed.
The Error Types correspond to the descriptions:
1. Refer to Congestion Query test (#600) for Abort and Fail 3601s.
o. Error Type 3073: RSCL (Remote Socket Control Link) or Link Status test
(#601) failed. This failure may be due to:
■
This circuit pack
■
The packet bus
■
The Packet Interface circuit pack.
p. Error Type 3330: Critical failure in packet-bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
2817
All buffers exhausted.
2819
Utilized buffers exceed threshold.
If:
Then:
Active buffers exceed threshold
C-LAN enters congested state.
If:
Then:
RSCL disconnects at link level
Link fails
Link cannot be reconnected quickly
Switch raises MINOR alarm
If the switch detects:
Then it:
1 error,
Resets circuit pack.
2 errors in 15 minutes,
Raises MINOR alarm.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...