Maintenance-Object Repair Procedures
555-233-143
8-426
Issue 1 May 2002
1, 2
FAIL
FAIL
The buffer level is nearly exhausted.
The C-LAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals up to 5 times.
2. If command continues to fail, examine the C-LAN port measurements to
determine what ports are heavily utilized and the processor occupancy of
the circuit pack.
Low processor occupancy when C-LAN congested indicates circuit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the C-LAN is congested due to traffic load.
1. To relieve congestion in the short term, selectively busyout ports (busyout
port UUcSSpp) on the Control LAN circuit pack.
2. To achieve a more permanent resolution, it may be necessary to move
ports on this circuit pack to other Control LAN circuit packs.
3. Consider replacing affected C-LAN ports with new ports.
3
FAIL
The C-LAN circuit pack is not operating normally and is congested.
PASS
Hardware setting and attached cable type match C-LAN circuit pack
administration. The circuit pack detects no errors.
Table 8-173.
Test #600 Congestion Query Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...