Maintenance-Object Repair Procedures
555-233-143
8-436
Issue 1 May 2002
Three trunk service states are specified by DS1 CO trunk maintenance:
Error Log Entries and Test to Clear Values
out-of-service
The trunk is in a deactivated state and cannot be used for either incoming
or outgoing calls.
in-service
The trunk is in an activated state and can be used for both incoming and
outgoing calls.
disconnect (ready-for-service)
The trunk is in an activated state but can only be used for an incoming call.
Table 8-178.
DS1 CO Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test trunk grp/mbr
1(a)
57408
1(a)
57487
15(b)
Any
Port Audit and
Update test (#36)
18(c)
0
busyout trunk
grp/mbr
WARNING
OFF
release trunk grp/mbr
130(d)
None
WARNING
ON
test trunk grp/mbr
257(e)
57392
DS1 CO Dial Tone
Seizure test (#314)
MINOR
WARNING
2
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set
to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service,
then the alarm will be upgraded to a MAJOR alarm.
OFF
513(f)
57393
DS1 CO Dial Tone
Seizure test (#314)
MINOR
WARNING
OFF
769(g)
57484
1025
DS1 CO Dial Tone
Seizure test (#314)
MINOR
WARNING
3
3.
Major alarms MO may be downgraded to Warning alarms based on the value used in the set options command.
OFF
test trunk grp/mbr r 2
1281
Conference Circuit
test (#7)
MINOR
WARNING
ON
test trunk grp/mbr l r 4
1537
NPE Crosstalk test
(#6)
MINOR
WARNING
ON
test trunk grp/mbr l r 3
1793(h)
test board UUCSS l
2562(i))
16665
2817(j)
52992
3840(k)
Port Audit and
Update test (#36)
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...