CO-TRK (Analog CO Trunk)
Issue 1 May 2002
8-465
555-233-143
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if
necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 8-186.
Test #3 CO Demand Diagnostic Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page