Maintenance-Object Repair Procedures
555-233-143
8-485
Issue 1 May 2002
8
DAJ1 (Server Duplication Memory
Board)
This MO supports Server Duplication Memory board. Testing for this MO is done
periodically and on demand. The periodic test runs the
read_err_reg
test
every 15 minutes. The demand-testing capabilities are the
read_err_reg
and
localloop
tests.
Alarm Log Entries
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Linux Command to
Run
1
1.
Usage:
testdupboard [-s] | [-l] | [-t arg] | [-?]
no argument Performs “short” test.
-s Short test, performs read_err_reg test,
this is also the default option.
-l Performs “short” tests, and localloop test
-t arg Specific test to perform. Possible values for
arg are: read_err_reg | localloop
-? Usage (this).
Full Name of MO
DAJ1
MAJOR
testdupboard
Server Dup Mem Board
DAJ1
MINOR
testdupboard
Server Dup Mem Board
DAJ1
WARNING
testdupboard
Server Dup Mem Board
Table 8-194.
DAJ1 Alarm Log Entries
EVENT
ID#
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Linux Test to Clear
Value
2 (a)
Read Error Register test
(EDC single bit)
WARNING
ON
testdupboard
3 (b)
Read Error Register test
(SDRAM multibit errors)
MAJOR
ON
testdupboard
4 (c)
DAJ1 Local Looparound
test
MINOR
ON
testdupboard
5 (d)
Read Error Register test
(Link Receiver CRC
Errors)
MINOR
ON
testdupboard
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...