DAT-LINE (Data Line Port)
Issue 1 May 2002
8-495
555-233-143
Table 8-201.
Test #171 Digital Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1000
ABORT
System resources required to run test are not available. The port may be in
use on a valid call. Use status data-module to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABORT
An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type #769.
1042
ABORT
Port under test is a TTI port and has only default translations with no assigned
extension. The executed test requires an assigned extension associated with
the port being tested. Therefore, this test cannot successfully execute.
1. If there is a need to execute the test on this particular port, then the tester
must ensure that the port is fully translated such that the port has an
assigned extension.
1180
ABORT
There is no Maintenance/Test circuit pack digital port available to carry out the
test.
1. Check to see if the Maintenance/Test digital ports are present. (Enter list
config command; ports 02 and 03 should show).
2. If the digital ports (02 and 03) on the Maintenance/ Test circuit pack are not
present, see
‘‘M/T-BD (Maintenance/Test Circuit Pack)’’
.
3. If the digital ports are present, retry the command at 1-minute intervals up
to 5 times.
1181
ABORT
No time-slots available to connect digital ports for the test.
1182
ABORT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABORT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. At least one Maintenance/Test circuit pack must be present in PN
1 of the system. There should be at least two such ports present. If the
ports are present, proceed to step 2. Otherwise, determine why no ports
appear in the list config display. Refer to “M/T-DIG” and “M/T-BD”.
2. Look for M/T-DIG errors in the Error Log. If present, see
(Maintenance/Test Digital Port)’’
3. If the ports are present and no errors are logged against them, retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...