Maintenance-Object Repair Procedures
555-233-143
8-528
Issue 1 May 2002
Port Audit Update Test (#36)
This test sends updates of the DID port translation for every port on the circuit
pack that has been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data includes:
■
Wink or immediate start trunk
■
Dial tone or rotary dialing trunk
■
Rotary dialing inter-digit timing
■
Network balance R/RC
■
Disconnect timing
Table 8-212.
Test #36 Port Audit Update Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1006
ABORT
The port is out of service, perhaps busied out.
1. Use display port UUCSSpp to determine the trunk group/member number
of the port. Use status trunk to determine the service state of the port. If
the port is out of service, wait until the port is in service and idle before
testing.
2. If the port status is in service and idle, then retry the command at 1-minute
intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run the test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...