Alarms, Errors, and Troubleshooting
555-233-143
4-52
Issue 1 May 2002
Figure 4-31.
S8700 Multi-Connect display errors input screen
shows the screen output for the display errors command.
Figure 4-32.
Screen output for display errors command
display errors Page 1 of 1 SPE A
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: Error List: errors
REPORT PERIOD
Interval: a From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category: PNC
Extension:
Trunk ( group/member ): /
display errors Page 9 SPE A
HARDWARE ERROR REPORT
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
AT01A ATM-NTWK 41 1 11/12/16:59 12/09/15:10 14 0 0 n n
AT01A ATM-NTWK 31 0 11/13/18:27 11/20/20:02 5 0 0 n n
AT02A ATM-NTWK 0 0 11/13/18:45 11/13/18:45 1 0 0 n n
AT02A ATM-NTWK 31 0 11/15/14:40 11/15/14:41 2 120 0 n n
AT01B ATM-NTWK 31 0 11/16/17:39 11/16/17:39 1 0 0 n n
AT01A ATM-NTWK 3 1 11/16/18:19 11/26/13:13 12 0 0 n n