DIG-LINE (Digital Line)
Issue 1 May 2002
8-549
555-233-143
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port was seized by a valid call during the test.
1. Enter display port UUCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the port is in use, wait until it is
idle before resetting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The installed circuit pack does not support this operation.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
System resources required to run this test are not available.
1. Make sure terminal is connected and repeat test.
2. If test fails replace terminal and repeat test.
3. Retry the command at 1-minute intervals up to 5 times.
14
FAIL
The primary channel is not operating properly. User impact may range from
noticing nothing to not being able to use the port.
1. Check the results of “Voice and Control Channel Local Loop test (#13).
2. If that test fails, suspect the Digital Line circuit pack. If that test passes
then replace the terminal.
3. If both tests fail, and component replacement does not change the results,
then:
a. Run circuit pack tests to check the tone generator circuit and the Tone
Detector circuit using test board UUCSS.
b. Resolve any problems that are detected on the Tone Generator circuit
or Tone Detector circuit.
Table 8-220.
Test #1201 Digital Terminal Remote Loop-around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...