DIG-LINE (Digital Line)
Issue 1 May 2002
8-551
555-233-143
Table 8-221.
Test #9 Digital Line NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1
ABORT
During testing of the primary information channel, system resources were not
available. Also, the port may have been busy during the test.
1. Enter display port UUCSSpp to determine the station extension of the
port. Use status station to determine the service state of the port. If the
port is in use, wait until it is idle before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
2
ABORT
During testing of DTDM, system resources may not have been available. Also,
the port may have been busy during the test.
1. Check if port is being used. If possible, disconnect by toggling disconnect
button on DTDM. Retry command after 1 minute.
!
WARNING:
This action will drop the call in progress.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Enter display port UUCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the port is in use, wait until it is
idle before testing. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic. Retry
the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...