DIG-LINE (Digital Line)
Issue 1 May 2002
8-559
555-233-143
■
Ringer Update test
—
This updates the digital telephone ringer state
according to the processor records.
■
DTMF Administration Update test
—
This is a message to the digital station
to refresh the default value that causes the station to send touch- tones
only in the primary information channel. This value is set initially when the
station is put in-service and every time the station’s state changes from
other states to in-service state.
Table 8-225.
Test #17 Station (Digital) Audits Test
Error
Code
Test
Result
Description / Recommendation
1
ABORT
Switchhook audit timed out.
2
ABORT
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat test.
2. If test fails, replace voice terminal and repeat test.
3
ABORT
The EPF/PTC has detected an overcurrent condition.
1. For a TN754 vintage 13 or earlier Digital Line circuit pack, use test
UUCSSpp long.
■
If Test #11 passes, then the EPF/PTC condition was cleared.
Rerun the Short Test Sequence.
■
If Test #11 does not pass, follow the repair procedures described
for Test #11.
2. Look for Error Type 769 logged against DIG-LINE and follow the
procedures in the associated footnote. If any additional problems are
found, rerun the test.
4
ABORT
Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5
ABORT
Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6
ABORT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, the release the port via release station extension.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required for this test are not available.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...