Maintenance-Object Repair Procedures
555-233-143
8-694
Issue 1 May 2002
Enter busyout fiber-link <fiber #>
fiber # represents the fiber-link number
associated with the TN574 DS1 CONV
complexes that are being upgraded to TN1654
DS1 CONV complexes.
Enter remove fiber-link <fiber #>
Remove the four TN574 DS1 CONV circuit packs
from the system.
Replace the TN574 Y-cables with appropriate
TN1654 Y-cables.
Replace the removed TN574 DS1 CONV circuit
packs with TN1654 DS1 CONV circuit packs.
Prior to installing the TN1654 boards, review the
prior section, TN1654 Board Configuration
Switch Settings.
If a TN1654 DS1 CONV board is connected to an
SNI board, upgrade the SNI to a TN573B or
greater.
Wait for the circuit packs to reset
Red and green LEDs will light and then go out.
Enter change circuit-packs <cabinet #>.
Update the form to show that TN1654 boards are
now being used instead of TN574 boards. Also
update the connected SNI, if applicable, to suffix
B.
cabinet # represents the cabinet associated
with a DS1 CONV board. The appropriate
change circuit-packs form needs to be updated
for all four DS1 CONV boards. Also, if needed,
re-add translations for connected EI boards.
Enter change system-parameters duplication.
Change the
Enable Operation of PNC
Duplication?
field to
y
.
Enable PNC duplication.
Enter add fiber-link <fiber #> to re-add the
fiber-link using TN1654 DS1 CONV circuit packs.
fiber # represents the fiber-link number
associated with the TN574 DS1 CONV
complexes that are being upgraded to TN1654
DS1 CONV complexes.
Enter test alarms long clear for category
exp-intf.
Wait 5 minutes for SNI-BD, SNI-PEER,
FIBER-LK and DS1C-BD alarms to clear, or enter
clear-firmware counters <a-pnc or b-pnc>
Enter status pnc
If either PNC’s state of health is not
“functional”, consult the PNC-DUP section of
the Maintenance Manual.
Table 8-268.
Upgrading TN574 DS1 CONV Circuit Packs in a fiber-link to
TN1654s—Duplicated PNC
—
Continued
Steps
Comments
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...