DS1 CONV-BD
Issue 1 May 2002
8-715
555-233-143
Board Options Audit (#795)
This test is nondestructive.
This test sends the administered circuit pack options to the DS1 CONV circuit
pack. Options are sent to both DS1 CONV circuit packs at the same time to
prevent any transitional mismatch of options.
The following data is sent to the TN574 DS1 CONV circuit pack:
■
system-reliability configuration
■
master and slave endpoints for framing (determined by the relative position
of the circuit pack to the media server)
■
facility mask (whether each facility is installed)
■
clock reference mask (whether:
— each facility can be used as a clock-reference source
— the board is being used as a network-timing source)
■
packet compatible mask (whether each facility is packet compatible)
■
facility information for line coding, framing mode, and line compensation
The following data is sent to the TN1654 DS1 CONV circuit pack:
■
system-reliability configuration
■
master and slave endpoints for framing (determined by the relative position
of the circuit pack to the media server)
■
facility mask (whether each facility is installed)
■
idle code
■
CRC-enabled/-disabled flag (sent in E1 mode only)
■
facility information for line coding and line compensation (sent in T1 mode
only).
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...