ETH-PT (Control LAN Ethernet)
Issue 1 May 2002
8-745
555-233-143
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 1—Ethernet Local Looparound test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
b. Error Type 513—Link Integrity Inquiry test (#1282) failed, or C-LAN port
detected loss of Ethernet link integrity.
Possible causes:
■
Cabling
■
Ethernet transceiver
1. Test the port (test port UUCSSpp long).
2. If the Link Integrity Inquiry test (#1282) fails, refer to its repair
procedure.
Table 8-290.
ETH-PT Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp s
1 (a)
0
Ethernet Local
Looparound test
(#1278)
MINOR
ON
test port UUCSSpp l r
3
513 (b)
0
Link Integrity Inquiry
(#1282)
MINOR
OFF
test port UUCSSpp r 2
769 (c)
0
WARNING
OFF
1281 (d)
0
1537, 1538 (e)
Session Status test
(#1286)
MINOR
OFF
1793–1920 (f)
2305–2560 (g)
2561–2816 (g)
3329 (h)
TCP/IP Ping test
(#1281)
WARNING
OFF
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...