Maintenance-Object Repair Procedures
555-233-143
8-752
Issue 1 May 2002
Session Status Test (#1286)
This nondestructive test determines the status of every Ethernet port session.
This test queries the system software on port session status.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
FAIL
Link integrity lost due to problem with attachment of Ethernet cable to the port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port and
to the bus.
3. Verify the C-LAN circuit pack’s link integrity LED is glowing.
4. Retry the test.
5. If problem persists, see Ethernet Local Loop-around test (#1278) repair
procedures.
PASS
The Ethernet Link Integrity test (#1282) detects good connections.
If the system software indicates that:
Then the switch:
Every port session is up (ALL UP)
Raises no alarm, or retires alarm
Some port sessions are up (SOME UP)
Raises WARNING alarm
Every port session is down (ALL DOWN)
Raises MINOR alarm
Table 8-294.
Test #1282 Link Integrity Inquiry Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...