EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-781
555-233-143
Error Log Entries and Test to Clear Values
Table 8-301.
EXP-INTF Error Log Entries
Error
Type
Aux
Data
1
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
2
0
Any
Any
Any
test board UUCSS
1
Any
EI Local TDM Looparound
test (#240)
MAJOR
ON
test board UUCSS r 2
2
EI Local TDM Looparound
test (#240)
MAJOR
ON
test board UUCSS r 2
18 (a)
0
busyout board UUCSS
WARNING
OFF
release board UUCSS
23 (b)
0
None
WARNING
OFF
125 (c)
None
MINOR
ON
131 (d)
None
MINOR
ON
257 (e)
Any
None
MINOR
OFF
513 (f)
5–7
None
MAJOR
ON
769 (g)
113
EI FOOF Query test (#238)
WARNING
OFF
test board UUCSS r 1
770
EI FOOF Query test (#238)
WARNING
OFF
test board UUCSS r 1
1025
Any
EI Control Channel test
(#316)
MAJOR
ON
test board UUCSS r 1
1281 (h)
EI Neighbor Query test
(#237)
MINOR
OFF
test board UUCSS r 1
1537
EI 2-way Transmission test
(#241)
MAJOR
OFF
test board UUCSS r 4
1538 (i)
None
MINOR
ON
1793
EI Lightwave Transceiver
Looparound test (#242)
MAJOR
ON
test board UUCSS l r
3
2305 (j)
118
None
WARNING
OFF
2306 (j)
3
None
WARNING
OFF
112
2561 (k)
Any
None
MINOR
ON
2817 (l)
Any
None
MINOR
ON
3073 (m)
Any
EI Packet Interface test
(#589)
MAJOR
OFF
test board UUCSS r 3
3074 (n)
2
EI Packet Interface test
(#589)
MAJOR
OFF
test board UUCSS r 3
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...