EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-789
555-233-143
Table 8-304.
Test #238 Expansion Interface Fiber Out-of-Frame Query Test
Error
Code
Test
Result
Description / Recommendation
1033
ABORT
The EI circuit pack does not have a fiber link administered to it. There is not
sufficient data to run test.
1. Issue the list fiber-link command to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack, but there should be add
the correct fiber using the add fiber-link command.
3. Retry the command.
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
EI circuit pack could not detect framing sequence.
1. If the EI circuit pack that is failing Test #238 is in the PN, and the red LEDs
are ON on a large number of circuit packs, then reseat any Tone-Clock
circuit packs in the PN.
2. Perform the
‘‘Fault Isolation for Fiber Links’’
.
3. Enter display errors and resolve any SNC-BD, TDM-BUS, TDM-CLK, or
SYNC errors.
PASS
The EI circuit pack has detected the valid framing signal on the fiber.
1. Refer to errors from other EI circuit pack, SNI tests, or DS1 CONV tests (if
present) if the link is still not functioning.
0
NO
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131).
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...