EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-795
555-233-143
1033
ABORT
The test cannot run because either the EI board does not have a fiber link
administered to it and there is not sufficient data to run the test, or there were
no other PNs administered that had its EI board In-Service.
1. Check fiber administration to insure that there is a fiber link administered to
this EI circuit pack.
2. If there is a fiber administered to this EI circuit pack, then some change in
the status of the ability of the EI circuit pack in the other PNs to
communicate with the EI or SNI circuit pack on the other end of its fiber has
occurred.
3. Test #237 and check for EXP-INTF circuit pack Error Type 1281 in the
Error Log for the EI circuit packs in these other PNs. If Error Type 1281 is
present and/or Test #237 does not pass, see repair procedures for Test
#237, in
.
4. If Test #237 passes, reseat the EI circuit pack. This is not destructive since
the circuit pack cannot be serving as the Expansion Archangel if it is not in
service.
1394
ABORT
The EI circuit pack is out of service and the test cannot be run. This condition
is due to a change in the EI circuit pack’s ability to communicate with the EI or
SNI circuit pack on the other end of the fiber.
1. Run Test #237, and check the Error Log for EXP-INTF Error Type 1281. If
Error Type 1281 is present or if Test #237 fails, see repair procedures for
Test #237, in
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1413
ABORT
This test requires the use of a Tone-Clock circuit pack in each of the PNs used
in this test. This abort code indicates that there are none of these circuit packs
located in one of the PNs.
1. Verify that there is a Tone-Clock circuit pack in the PN where the EI circuit
pack under test resides.
2. In a Direct Connect configuration, verify that there is a Tone-Clock circuit
pack in the PN where the neighbor EIEI circuit pack circuit pack resides.
3. In a Center Stage Switch configuration, verify that there is at least one
other PN, besides the PN where the EI circuit pack under test resides, with
a Tone-Clock circuit pack.
Table 8-306.
Test #241 Expansion Interface 2-Way Transmission Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...