Maintenance-Object Repair Procedures
555-233-143
8-796
Issue 1 May 2002
1414
ABORT
This test requires the use of an active Tone-Clock circuit pack in each of the
PNs used in this test that does not have a MAJOR or MINOR alarm logged
against it. This abort code indicates that the active Tone-Clock circuit pack in
one of the PNs being used for the test has a MAJOR or MINOR alarm logged
against it.
1. Enter display alarms and resolve every TONE-BD and TONE-PT alarm.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The test tone was not detected correctly in either direction.
1. Run the test for the active Tone-Clocks on the PNs for which the EI circuit
pack under test provides a link. This will determine whether dial tone is
being supplied.
2. Perform the
‘‘Fault Isolation for Fiber Links’’
1 or 2
FAIL
The test tone was detected correctly in one direction, but not the opposite
direction.
1. Test for the active Tone-Clocks on the PNs for which the defective EI board
provides a link. This determines if the dial tone is supplied.
2. Perform the
‘‘Fault Isolation for Fiber Links’’
Center Stage: These failure codes are possible on a Center Stage Switch
configuration only when there is just one other PN available for looping back
the test tone.
1. Perform the
‘‘Fault Isolation for Fiber Links’’
3 or 4
FAIL
The failure codes only apply to a system equipped with a Center Stage Switch.
They indicate that the test aborted or failed for the first connection from the EI
board under test to another PN, and that the test tone was detected correctly in
one direction, but not the opposite direction when the connection was between
the EI board under test and a different PN than was used in the first connection.
1. Run the test for the active Tone-Clocks on the PNs for which the defective
EI board provides a link. This determines if the dial tone is being supplied.
2. Perform the
‘‘Fault Isolation for Fiber Links’’
Table 8-306.
Test #241 Expansion Interface 2-Way Transmission Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...