Maintenance-Object Repair Procedures
555-233-143
8-802
Issue 1 May 2002
2060
ABORT
The link on the packet bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continue to abort, enter display errors and resolve any PKT-INT
errors.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
The test did not detect the test tone through the loop-around connection.
NOTE:
The packet portion of this test was not run since the circuit portion failed.
1. Test the active Tone-Clock on the PN that contains the defective EI circuit
pack to verify that dial tone is being supplied.
2. If the Tone-Clock is healthy, issue the test board UUCSS long on the EI
circuit pack.
3. If this test continues to fail, replace the EI circuit pack or transceiver. Then
reissue the test board UUCSS long on the new EI circuit pack.
2
FAIL
The test tone was transmitted and detected correctly, but the correct data
packet was not detected by the TN1655 Packet Interface circuit pack.
1. Test the TN1655 Packet Interface circuit pack to verify that it is functioning
properly. If any tests fail, investigate those tests and repair the Packet
Interface circuit pack.
2. If the Packet Interface circuit pack checks out OK, enter display errors
and display alarms and resolve any SNI-BD and FIBER-LK alarms or
errors (Center Stage Switch only) and DS1 CONV-BD alarms or errors (if
present).
3. Issue the test board UUCSS long command on the EI board.
4. If Test #242 continues to fail, replace the EI board. Then issue the test
board UUCSS long command on the new EI board.
5. If Test #242 continues to fail, replace the lightwave transceiver, reset the
circuit pack and issue the test board UUCSS long command on the EI
circuit pack.
Table 8-307.
Test #242 Expansion Interface Lightwave Transceiver Looparound
—
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...