EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-817
555-233-143
9999
ABORT
EI circuit pack reset successfully. Could not perform initialization test results
query because link to PN is not up.
1. Execute release board PCSS. Wait one minute. Issue the display error
command. If you see Error Type 2049 logged against this EI circuit pack,
then the EI Test has failed with an error code equal to the aux data of this
entry. Otherwise, the initialization tests have passed.
12000
ABORT
EI circuit pack reset successfully. Response to the initialization test results
query was not received within the allowable time period.
12100
ABORT
EI circuit pack reset successfully. System resources required to run
initialization test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
12026
ABORT
EI circuit pack reset successfully. It responded with an unknown reply to the
query for the results of its initialization tests.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, replace the circuit pack or transceiver.
1
FAIL
The EI did not successfully reset.
1. If the EI circuit pack is in the PN, the PN’s Maintenance board may be
holding the EI circuit pack reset. Attempt to rectify this condition by
executing the test maint P long command on the Maintenance board in
the same PN.
2. If step 1 was not successful in releasing the EI circuit pack, temporarily
remove the PN’s Maintenance circuit pack.
3. Repeat the reset board PCSS command.
4. If reset continues to fail, replace circuit pack.
5. Insert PN’s Maintenance circuit pack if it was removed.
2
FAIL
The EI circuit pack was successfully reset, but it did not begin running after the
reset.
1. If the EI circuit pack is in the PN, temporarily remove the PN’s Maintenance
circuit pack.
2. Repeat the reset board PCSS command.
3. Re-insert the PN’s Maintenance circuit pack if it was removed.
Table 8-311.
Test #224 Expansion Interface Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...