Maintenance-Object Repair Procedures
555-233-143
8-820
Issue 1 May 2002
5016,
5017,
5018,
5019,
5032,
5033,
5048,
5064,
5080,
5096,
5112
FAIL
Initialization failure: the EI circuit pack reset successfully and restarted
execution, but the EI circuit pack detected communication errors during
hardware initialization. The nature of the failure may prevent the EI circuit pack
from communicating with its neighbor EI circuit pack on the opposite end of the
fiber. The fault itself may be either on the EI circuit pack or on the lightwave
transceiver.
1. If every other test on this EI circuit pack is passing and no other errors
have been logged against this circuit pack, replacement of the lightwave
transceiver or the circuit pack is recommended, but not critical.
2. If some tests on this EI circuit pack are failing or other errors have been
logged against this circuit pack, replace the lightwave transceiver and/or
the EI circuit pack.
PASS
The EI was successfully reset, and it restarted execution. It also passed all of
its initialization tests and detected a lightwave transceiver. Remove the EI
circuit pack from the busyout state by using the release board PCSS
command.
1. Execute test board PCSS short command. Refer to errors for each test.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 8-311.
Test #224 Expansion Interface Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...