Maintenance-Object Repair Procedures
555-233-143
8-826
Issue 1 May 2002
PN Warm Restart (#956)
The PN Warm Restart, or PN Reset Level 1, using the command reset
port-network P level 1 is used to restart an PN that has not been taken out of
service. It is the least severe of the PN restart levels and is used in an attempt to
preserve the state of the system as much as possible, thereby reducing user
impact. This restart is attempted on a PN if it is still in service, or as a result of a
system technician-demanded PN Warm Restart.
During an PN Warm Restart all calls are preserved including voice, data, and
packet calls. Once an event has occurred that requires a warm restart, service is
fully restored within 35 seconds.
Table 8-314.
Test #956 PN Warm Restart
Error
Code
Test
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to execute this reset.
1. Retry the command at 1-minute intervals up to 3 times.
1386
ABORT
The system link to this PN is unavailable and cannot be used. This reset
cannot be executed without the link being operational.
1. See SYS-LINK and resolve the link problem.
1387
ABORT
This PN is not in a state where it is possible to perform a Warm Restart on the
PN. It is necessary to perform an PN Cold Restart (PN Reset Level 2) because
of one of the following reasons:
■
The PN is in an out-of-service state.
■
Insufficient time has elapsed since the last PN Cold Restart was
performed on this PN.
2000
ABORT
Response to a request made in the internal portion of this reset procedure was
not received within the allowable time period.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
Internal system error
1. Retry the reset command at 1-minute intervals up to 3 times.
PASS
The PN Warm Restart procedure completed successfully.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...