FIBER-LK (Fiber Link)
Issue 1 May 2002
8-833
555-233-143
d. The media server is not acknowledging messages from the DS1 CONV
circuit pack or the DS1 CONV circuit pack does not have a processor
route. This pattern indicates a probable software problem.
In addition to the traditional red, green, and amber LEDs, the DS1 CONV circuit
pack has four green LEDs that indicate whether a receive signal is present for
each DS1 facility.
Error Log Entries and Test to Clear Values
Notes:
a. The failure audit test (#777) should be run to confirm whether the error still
exists.
b. This error indicates problem with the control path to the neighbor.
c. This error indicates that the fiber link has been busied out via the busyout
fiber F P command. To resolve this error, release the fiber link with the
release fiber F P command.
d. This error indicates problem with the circuit path to the neighbor.
e. This error indicates problem with the packet path to the neighbor.
Table 8-319.
Fiber Link Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test fiber-link F P r 1
1 (b)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
18 (c)
0
busyout fiber F P
WARNING
OFF
release fiber F P
257 (d)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
513 (e)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
76 9(f)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
1025 (g)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
1281 (h)
any
failure audit (#777) (a)
MAJOR, MINOR,
WARNING
OFF
test fiber-link F P r 1
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...