FIBER-LK (Fiber Link)
Issue 1 May 2002
8-835
555-233-143
Table 8-322.
Tests Run for an EI-to-SNI Fiber Link
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Fiber
Sequence
D/ND
1
1.
D = Destructive, ND = nondestructive
EI Out-of-Frame Query test (#238)
X
X
ND
EI Neighbor Query test (#237)
X
X
ND
Configuration audit (#759)
X
X
ND
Failure audit (#777)
X
X
ND
Fiber Out of Frame query (#989)
X
X
ND
Destructive Facility test (#757)
X
D
Off-Board Destructive Facility test (#756)
X
D
Fiber Link Reset test (#768)
X
D
Table 8-323.
Tests Run for an SNI-to-SNI Fiber Link
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Fiber
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Configuration audit (#759)
X
X
ND
Failure audit (#777)
X
X
ND
Fiber Out of Frame query (#989)
X
X
ND
Destructive Facility test (#757)
X
D
Off-Board Destructive Facility test (#756)
X
D
Fiber Link Reset test (#768)
X
D
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...