Maintenance-Object Repair Procedures
555-233-143
8-876
Issue 1 May 2002
Screen 8-6.
Display Firmware Image(s) screen
4. Ensure that both the Active Image and the Reset Image fields are Yes for
Image 2.
NOTE:
The firmware image filename (the file that you downloaded to the
TN2501AP circuit pack) does not appear on this screen. Ensure that
you have copied the correct file to the circuit pack and have set the
proper firmware image file (set boot-image).
Error Log Entries and Test to Clear Values
Table 8-332.
FW-DWNLD Maintenance Error Log Entries
Error
Type
Aux Data
Cause Of Error
Alarm
Level
On/Off
Board
Test to Clear Value
257(a)
See
associated
note
Download
failure
MINOR
OFF
test firmware download
UUCSS
258(b)
See
associated
note
Download
failure
MINOR
OFF
test firmware download
UUCSS
259(c)
See
associated
note
Download
failure
MINOR
OFF
test firmware download
UUCSS
513(d)
See
associated
note
Download
failure
MINOR
OFF
test firmware download
UUCSS
796(e)
See
associated
note
Firmware
download
request
MINOR
OFF
test firmware download
UUCSS
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 02
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No
Reboot Image: Yes No
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...