GPTD-PT (General-Purpose Tone Detector Port)
Issue 1 May 2002
8-885
555-233-143
Technician-Demand Tests: Descriptions and
Error Codes
Always investigate tests in the order presented below when inspecting errors in
the system. For example, by clearing error codes associated with the Tone
Detection Verification test (#42), you may also clear errors generated from other
tests in the testing sequence.
Tone Detection Verification Test (#42)
This test verifies that the call-progress tone-detection and the tone-level
measurement capabilities of the GPTD port are functioning properly.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Tone Detection Verification test (#42)
X
X
ND
Tone Detector Audit/Update test (#43)
X
X
ND
Table 8-337.
Test #42 Tone Detection Verification Test
Error
Code
Test
Result
Description / Recommendation
ABORT
The system was not able to allocate every resource needed for this test, or
there was an Internal system error.
1
ABORT
The system could not allocate every resource needed to test the call-progress
tones.
1001
ABORT
The system was unable to put the GPTD port in the appropriate mode to test it.
1002
ABORT
The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily loaded,
then test the TDM-BUS via the test tdm [1 | 2] command.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...