H323-STN (H.323 IP Station)
Issue 1 May 2002
8-901
555-233-143
1007
FAIL
The system could not PING the registered endpoint via the C-LAN.
1. Verify that at least one destination reachable through this port. PING this
destination (ping ip-address xxx.xxx.xxx.xxx).
2. If the PING to any destination is successful through this port, the link is up.
3. If PING to every destination fails, test the C-LAN port (test port UUCSSpp
short), and follow repair procedures for Session Status test (#1286)
failures.
4. If only this station cannot be pinged:
■
Make sure the PC is up
■
Make sure the PC has a network connection (ethernet or dialup)
■
Check the ethernet cabling
PASS
The system can successfully send IP packets to the registered endpoint from
the C-LAN.
Table 8-346.
Test #1373 Signaling Path PING Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page