HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-907
555-233-143
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. For example,
by clearing error codes associated with the Local Digital Looparound test (#58),
you may also clear errors generated from other tests in the testing sequence.
Table 8-349.
System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = nondestructive
NPE Crosstalk test (#6)
X
ND
Hybrid Electronic Power Feed test (#56)
X
ND
Hybrid Circuit and Conference Circuit test (#57)
X
ND
Local Digital Looparound test (#58)
X
ND
Remote Digital Looparound test (#59)
X
X
ND
Station Lamp Update test (#60)
X
X
ND
Station Audits test (#61)
X
X
ND
Ringer Update test (#62)
X
X
ND