HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-911
555-233-143
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Electronic Power Feed test passed. The message to turn on the power to the
station was successfully sent to the port.
1. Although this test never actually returns a FAIL result (except for the
previous Internal system error), it logs an error if the overcurrent case is
detected by the hardware. Check the Error Log for any entries with Error
Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds after
completion of this test, it is safe to assume that the test sensed no
problems with the power to the station. To verify that the station is
powered up correctly, run a self-test on the station, if available, and check
that every feature button is operating.
3. If Error Type 257 appears in the Error Log, this indicates some problem
with the power to the station. Check for a short in the wiring, a damaged
jack, a defective voice terminal, or an incorrect type of terminal.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 8-351.
Test #56 Hybrid Electronic Power Feed Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...