Maintenance-Object Repair Procedures
555-233-143
8-912
Issue 1 May 2002
Hybrid Circuit and Conference Circuit Test (#57)
This test checks two different port circuit functions. The Hybrid Circuit test
performs an analog reflective looparound measurement on the port’s hybrid
circuitry. The conference circuit test performs a conference test on the port’s
NPE.
For the Hybrid Circuit Test results to be valid, a voice terminal must be connected
to the port being tested. The test instructs the on-board microprocessor to put the
port in analog reflective looparound mode.
The Conference Test is performed only if the Hybrid Test passes. The
Conference Circuit Test verifies that the Network Processing Element (NPE) is
able to correctly conference several test tones together.
Table 8-352.
Test #57 Hybrid Circuit and Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1001
ABORT
Could not allocate the necessary system resources to run this test. This could
be a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...