INADS (INADS Link)
Issue 1 May 2002
8-927
555-233-143
Table 8-358.
INADS Link Test Error Log Entries
Error
Code
Test
Result
Description / Recommendation
1
0
A test call was successfully placed to the alarm receiver. No trouble found.
2
0
Informative error indicating that alarm origination was disabled at the time of
the test. The test runs even though alarm origination is disabled.
1. If desired, enable Alarm Origination via the Maintenance-Related System
Parameters form.
2. Repeat the test.
3
0
The alarm receiver’s connection is currently in use.
1. Wait 10 minutes, and retry this command.
4
0
The alarm receiver did not answer the test call.
1. Verify that the alarm receiver is up and running.
2. Verify the accuracy of the alarm receiver’s phone number and the system’s
product ID using the Maintenance-Related System Parameters form.
3. Enable alarm origination via the Maintenance-Related System Parameters
form.
Test the SYSAM (System Access Maintenance) by issuing the test
maintenance a | b command.
4. Retry the command.
5
0
The alarm receiver’s phone number is not assigned.
1. Assign the alarm receiver’s phone number via the Maintenance-Related
System Parameters form.
2. Retry the command.
6
0
The alarm receiver did not return an acknowledgment for the “test inads alarm”
message.
1. Verify the accuracy of the alarm receiver’s phone number and the system’s
product ID via the Maintenance-Related System Parameters form.
2. Verify that the alarm receiver is up and running.
3. Retry the command.
7
0
The alarm receiver returned a negative acknowledgment for the “TESTING
INADS LINK” message.
1. Verify that the product IDs match in the customer’s switch and the alarm
receiver’s database. Use the Maintenance-Related System Parameters
form to identify the product ID of the switch.
2. Rerun the test.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...