IPMEDPRO (IP Media Processor Circuit Pack)
Issue 1 May 2002
8-933
555-233-143
k. Error Type 2049—Indicates that the processor, specifically the Power PC,
860T hardware is failing. The PPC provides the Angle functionality as well
as the UDP/IP interface; an attempt is made to reset the board
automatically. For the repair procedure, see associated Test #1406. If the
reset fails, the board is probably bad and should be replaced.
l. Error Type 2305—Indicates an IP address inconsistency between switch
software and the IPMEDPRO board. If this error occurs, an attempt will be
made to download the IP address again. If the board still refuses the IP
address, the board will be reset.
m. Error Type 2561—Indicates that the ping test has failed. The diagnostics
that are run by this failure start up analysis testing and rerun the test.
Testing will continue until the problem is cleared. However, once the
counter reaches threshold, an attempt will be made to refresh the IP
address to the board.
n. Error Type 2817—Indicates an Ethernet hardware failure on the TN2302
circuit pack. The diagnostic strategy for this inline error is to take the
switch resources associated with all of the DSPs out of service and then
reset the Ethernet hardware. The reset of the Ethernet hardware will cause
an uplink response as to whether the reset passed or not. There are
several error conditions that can be sent up in the error message for this
problem; they will all be treated as the same failure by switch software. For
the repair procedure, see associated Test #1406.
o. Error Type 3073—Associated with a circuit board reset. The diagnostic
strategy for these inline errors is to take the switch resources associated
with all of the DSPs out of service and then reset the board, as the failure of
the Scotch is severe enough to warrant a board reset. After the board
reset a query can be made again for the health of the Scotch devices to
verify whether they are OK. If they are, the alarm and counters will be
cleared; if not, the alarm will be left up, all DSPs will be left out of service,
and maintenance diagnostics will stop. If the board continues to fail with
this error type, replace the TN2302.
p. Error Types 3840, 3841—Indicate inconsistent downlink message. These
errors are not service affecting. No action is required.
q. Error Type 3999—Indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
Error Type 1538 is also present, then the circuit pack was taken out of
service due to hyperactivity. If Error Type 1538 is not present, then the
circuit pack has not been taken out of service, but it has generated 50
percent of the messages necessary to be considered hyperactive. This
may be completely normal during heavy traffic periods. However, if this
error type is logged when the circuit pack is being lightly used, it may
indicate a problem with the circuit pack or the equipment attached to it.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...