Maintenance-Object Repair Procedures
555-233-143
8-936
Issue 1 May 2002
Table 8-362.
Test #53 SAKI Sanity Test
Error
Code
Test
Result
Description / Recommendation
None
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals up to 5 times.
1015
ABORT
Port is not out of service.
1. Busy out the circuit pack.
2. Execute command again.
2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals up to 5 times.
2803
ABORT
It is necessary to reset the board.
1. Use the change ip-interfaces form to disable the Media processor IP
interface.
2. Execute the command again.
1
FAIL
The circuit pack failed to reset.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
2,
2000
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS
The circuit pack initializes correctly.
Run the short test sequence.
Any
NO
BOARD
This is normal if the test is being done when (a) the board is not physically in
the system or (b) the system is booting up. Otherwise, there is some
inconsistency between the physical configuration and the data kept in the
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...