IPMEDPRO (IP Media Processor Circuit Pack)
Issue 1 May 2002
8-949
555-233-143
2807
ABORT
The specified IP Media processor board has been disabled on the ip-interfaces
form.
10XX
XX =
PN #
FAIL
The test tone was not successfully sent from the IP Media processor specified
in the test command, and not successfully received by an IP Media processor
in the PN specified in the error code (XX). Source to destination direction
failed. Destination to source direction not tested.
XX = PN number.
■
Resolve all other board alarms for the specified source IP Media
processor.
■
Resolve all other board alarms for the IP Media processor boards in the
destination PN.
■
Use the ping and traceroute commands to localize the problem to the
customers LAN/WAN IP network.
20XX
FAIL
The test tone was successfully sent from the IP Media processor specified in
the test command and received by an IP Media processor in the PN specified
in the error code (XX).
The test tone was not successfully sent in the reverse direction. Destination to
source direction failed. Source to destination direction passed.
■
Resolve all other board alarms for the specified source IP Media
processor.
■
Resolve all other board alarms for the IP Media processor boards in the
destination PN.
■
Use the
ping and traceroute
commands to localize the problem to the
customers LAN/WAN IP network.
PASS
The customer network is functioning properly. The test tone was transmitted
and received successfully between the IP Media processor specified in the test
command and every other IP Media processor in the set of connected IP
network regions.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues, if
applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the NCE chip on board may be bad. Replace
the board and retest.
Table 8-368.
Long IP 2Way Transmission Test (#1506) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...