Isolating and Repairing Packet-Bus Faults
Issue 1 May 2002
4-95
555-233-143
Following is an example of a stand-alone mode display. The symbols above the
line represent specific leads on the backplane. The bottom line indicates the
following:
NOTE:
This information is available only from the stand-alone mode. It is not
available from the MT or a remote login.
O
Open lead
S
Shorted lead
blank No
fault
L L L L L L L L L L H H H H H H H H H H S S S L
P 0 1 2 3 4 5 6 7 8 P 0 1 2 3 4 5 6 7 8 S F B F
_______________________________________________
S S O
Command: