Maintenance-Object Repair Procedures
555-233-143
8-982
Issue 1 May 2002
3905
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
If customer is complaining of unexpected intercept tones
when accessing ISDN trunks or PRI endpoints and no other
cause can be found, escalate the problem and provide the
next tier with this Error Log information.
3906
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
If customer is complaining of unexpected intercept tones
when accessing ISDN trunks or PRI endpoints and no other
cause can be found, escalate to the problem and provide
the next tier with this Error Log information.
3909
A request to use a network
service has been made, but
the network has rejected
the request because the
requested service is not
implemented.
Follow the previous recommendation for Error Type 3890.
3910
Only restricted digital BC
available.
3919
Service or option not
implemented, unspecified.
Used when no other cause
in this class applies.
3928
A call was denied because
of a basic incompatibility
between the type of call and
either the facilities selected
by the routing pattern or the
called user itself.
This error might be helpful as a clue if the customer
complains of receiving unexpected intercept tone after
accessing ISDN trunks or PRI endpoints. Determine the
trunk group from the circuit pack and port number (in the
aux data field) and then check the BCC fields of the
pertinent routing patterns. Also, investigate whether or not
the calling and called endpoints are compatible (for
example, some ISDN switches may not allow a voice station
to call a data extension).
3942
Timer expiry: T310
time-out, no answer to
CALL PROCEEDING.
Table 8-387.
Descriptions and Recommendations for Error Types 3842-3942
—
Continued
Error
Code
Description
Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...