ISDN-SGR (ISDN-PRI Signaling Group)
Issue 1 May 2002
8-985
555-233-143
Table 8-388.
Test #637 Remote Layer 3 Query
Error
Code
Test
Result
Description / Recommendation
1006
ABORT
There are no associated B channels in an ISDN in-service or maintenance
service state. This is a NORMAL ABORT.
1. Administer or release an ISDN trunk or PRI endpoint before retrying the
test. For an ISDN trunk, use the status trunk group#/member#
command to verify the ISDN trunk state. For a PRI endpoint use status
pri-endpoint extension. Then, retry this test when at least one B channel
is in the in-service or maintenance states.
1113
ABORT
The signaling channel is down. Therefore, no messages can be sent to the
far-end switch or terminal adapter.
1. Examine the results of Tests #636 and #639 and follow recommendations
provided there.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500
or
none
ABORT
Internal system error or administration problem
1. Determine whether any B channels are administered. If not, then this is a
normal ABORT, since this test cannot run unless at least one B channel is
administered. If at least one B channel is administered, there is an internal
system error. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error. See description of ABORT with error code 2500.
PASS
A message was composed and sent to the far-end switch or terminal adapter.
The ISDN PRI specification allows up to 2 minutes for a reply. Check the Error
Log for
‘‘ISDN-SGR (ISDN-PRI Signaling Group)’’
for errors of type 2305 for
evidence of a Remote Layer 3 Query failure. If no new errors were logged
since this test was run, then this switch and the far-end switch or terminal
adapter can exchange call control messages. If there is still a problem with a
particular ISDN trunk or PRI endpoint, busyout the trunk and run the long test
sequence, paying particular attention to the results of Test #258 (ISDN Test
Call).
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...