ISDN-TRK (DS1 ISDN Trunk)
Issue 1 May 2002
8-1005
555-233-143
Call State Audit Test (#257)
If a call is active on the trunk, the switches on both sides of the connection should
agree on the ISDN state of the call, as defined in the ISDN Protocol Specification.
This test audits internal call state data by querying the far-end switch as to the
ISDN state of the call. It can be helpful when trying to clear a hung call. If the
internal call state data on the near-end switch is different than that of the far-end
switch, then the call will be torn down.
As with Test #256 (Service State Audit), a PASS simply means that an appropriate
message was composed and sent to the far-end switch. The ISDN Specification
allows up to 2 minutes for a reply. If a reply is not received within the 2-minute
window, a protocol time-out violation will be recorded in the error log against the
associated signaling channel (ISDN-LNK, Error Type 1).
Table 8-399.
Test #257 Call State Audit Test
Error
Code
Test
Result
Description / Recommendation
1018
ABORT
Maintenance is disable on this trunk.
1. Enable maintenance by entering ‘‘y’’ in the ‘‘Maintenance Tests?’’ field on
page 2 of the change trunk-group form.
1019
ABORT
An audit is already in progress.
1. Wait 2 minutes and try again.
1113
ABORT
The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #255 (Signaling Link State Check).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116
ABORT
The trunk is in an out-of-service ISDN service state.
1. A call cannot be present if the trunk is in an ISDN out-of-service state, so a
call state audit would be inappropriate. No action necessary. (Use the
status trunk group#/member# command to investigate the ISDN state of
the trunk).
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This switch sent a call state auditing message to the far-end switch to verify the
state of the call active on this trunk. If a call state mismatch is found, then the
call will be torn down within two minutes. If no call was active, then no
message was sent.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...