ISDN-TRK (DS1 ISDN Trunk)
Issue 1 May 2002
8-1011
555-233-143
2209,
2210
ABORT
Could not allocate the necessary system resources to run this test. Follow
recommendations for ABORT code 2100.
2211
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2212
ABORT
Call ended by unexpected disconnect.
1. Wait 1 minute, and then try again.
2213
ABORT
The call has timed-out, perhaps because of a lack of system resources. Follow
recommendations for ABORT code 2035.
2214
ABORT
Call ended by unexpected disconnect.
1. Wait 1 minute, and then try again.
2215,
2216,
2217,
2218,
2219
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2220
ABORT
Call ended prematurely.
1. Wait 1 minute, and then try again.
2221,
2222,
2223,
2224,
2225,
2226
ABORT
Internal system error. Follow recommendations for ABORT code 2012.
2227
ABORT
Could not allocate the necessary system resources to run this test. Follow
recommendations for ABORT code 2100.
2042
FAIL
Comparison of data sent to data received indicates a loss of integrity on the
communications path.
1. Take the trunk out of service and check the quality of the DS1 connection,
including the transmission facility and any external equipment such as
DACs, CSUs, etc. Use test isdn-testcall and status isdn-testcall
commands to get the bit and block error rates.
PASS
The test pattern was sent and received properly. If the synchronous test call
was performed (long test sequence), this indicates that the communications
path is operating properly. If the test isdn-testcall command was used, PASS
indicates only that the test call was established. Use the status isdn-testcall
command to get the bit and block error rates detected by the test. If the bit and
block error rates are not acceptable, perform a complete analysis of the DS1
facility including the transmission facility and any external equipment such as
DACs, CSUs, etc.
Table 8-400.
Test #258 ISDN Test Call —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...