MAINT (PN’s Maintenance Circuit Pack)
Issue 1 May 2002
8-1029
555-233-143
Sanity Handshake Test (#106)
This test checks the ability of an PN’s Maintenance circuit pack’s to respond to
queries. A message is sent to the PN’s Maintenance circuit pack which then
sends a message back. If the response message is received, then the
Maintenance circuit pack is queried for the PN cabinet type (valid PN cabinet
types are single carrier and multicarrier cabinets). The Maintenance circuit pack
reads pins on the backplane of carrier A that identify the type of cabinet and report
this information. If a valid cabinet type is returned, then the test passes.
Table 8-406.
Test #106 Sanity Handshake Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error.
1000
ABORT
System resources required for this test are not available.
2000
ABORT
Response to cabinet query was not received in the allowable time period.
2033
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2046
ABORT
The PN’s Maintenance circuit pack reported an invalid cabinet type. Not
knowing the cabinet type of the PN will prevent all PN environment
maintenance from running.
1. Retry the command.
2. If the test continues to abort with 2046, then either the PN’s Maintenance
circuit pack is defective, or the PN cabinet’s wiring is defective. First,
replace the Maintenance circuit pack.
3. If the test continues to abort with 2046, then the PN cabinet’s wiring is
defective in the A carrier, and the PN’s Maintenance circuit pack cannot
read the backplane pins to determine the cabinet type.
10601
ABORT
Test disabled via software patch.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...