MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 May 2002
8-1045
555-233-143
lists the TN802 LCD messages that you might see if installing or
servicing an IP Trunk.
Support for Laptop PCs
Field technicians can access the TN802 circuit pack through:
1.
‘‘pcANYWHERE® Client Software’’
2.
‘‘Directly-Connected Keyboard, Monitor, Mouse’’
pcANYWHERE
®
Client Software
1. Attach a male-to-male serial cable and a NULL modem connector (if
not built into the cable you use) to the COM2 connector (Note 8 in
) Attach the other end to the serial port
of your laptop.
2. Launch the pcANYWHERE
®
application.
3. Click on Add Remote Control Item.
4. In the Properties window, choose the communication port to which
you connected the cable in Step 1.
5. Click on Details and configure the settings (
Table 8-416.
TN802 LCD messages for IP trunks
Display
Explanation
PC BOOT
The TN802 MAPD PC is booting up.
IP TRK #
IP Trunk application is running (# character blinks).
IML DWN #
Internal error on the IP Trunk. System shuts down and
sends and error message to the board.
MSHUT #, where both
MSHUT and # are
blinking
The system is in the process of shutting down due to a front
panel button press. Do not attempt to remove board.
MSHUT #, where # is
blinking
The system has shut down gracefully.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...